Software Setup; Only) - Graco PR-X Setup - Operation - Repair

Fixed ratio system
Table of Contents

Advertisement

Software Setup (For Profinet
Communication Mode Only)
If you want to change the PR-X system from I/O
communication mode to Profinet communication mode,
order SD card 18C277. Insert the SD card in the
indicated slot before setting the IP address.
Insert the SD card
1. Turn off the control box power.
2. Remove the control box cover.
3. Insert the SD card.
F
. 43 Insert the SD Card
IG
3A7526B
Insert the SD card here
PLC IP Address Setup
1. Start PR-X control box and push 'Settings' button on
the 'Start Center' screen.
2. Select 'Service & Commissioning' on the 'Settings'
screen.
3. Select 'Assign PLC Address' from the 'Service &
Commissioning' list, then touch the cycle in the
middle of screen to see complete information.