Manual Screen 1 - Graco PR-X Setup - Operation - Repair

Fixed ratio system
Table of Contents

Advertisement

Manual Screen 1

F
. 18 Manual Screen 1
IG
On the Manual Screen, press 'F1' or select the
button to display the Manual Screen 2. Press 'F4' or
select the
button to execute the current operation
selected from 'Function mode' dropdown list
Select the
button to display the System Main
Screen. This button can only be selected when the
system is in standby or alarm mode. When the operator
has entered the System Main Screen, the system will
not work in Automation mode.
The content and functions of this screen are as follows:
3A7526B
Function mode operation select
Function includes 7 operations: Homing, Pre-charge,
Shot dispense, Bead dispense, Reload,
Depressurization and Purge.
Flowrate and target volume
Parameter setting of flow rate and target volume.
Progress bar and actual dispense volume
Shot mode: Displays the progress bar showing the
completion of the current target and the actual
dispensing volume.
Bead mode: The progress bar always displays
.
100%. The actual dispensing volume will increase
during bead dispensing and the target volume will
display a value consistent with the actual volume.
Current pressure, motor torque and piston position
Current pressure
-
Part A: Current pressure of A material.
-
Part B: Current pressure of B material.
Motor torque: The torque of the drive motor is
shown in NM.
Piston position: Displays how much material is in
the cylinders (0-100%). When the rod slider is at the
home position, 'Piston position' will show 100%.
When the slider moves to the 'empty' position,
'Piston position' will show 0%.
HMI Display Operation and Identification