Advanced Screen 2 - Graco PR-X Setup - Operation - Repair

Fixed ratio system
Table of Contents

Advertisement

HMI Display Operation and Identification

Advanced Screen 2

2
F
. 37 Advanced Screen 2
IG
On the Advanced Screen 2, press 'F1' or select the
button to return to the Advanced Screen 1.
The content and functions of this screen are as follows:
Dispense valve
Selecting this button enables testing of the MD2
Dispense Valve (AE) by controlling the opening or
closing of the valve. When the MD2 Dispense Valve
(AE) is open, the button will be green; when the MD2
Dispense Valve (AE) is closed, the button will be gray.
Inlet valve A and inlet valve B
Selecting each of these buttons enables testing of inlet
valve A and B (AL or AM), respectively, by controlling
the opening or closing of the valve. When the Inlet Valve
(AL or AM) is open, the button will be green; when the
Inlet Valve (AL or AM) is closed, the button will be gray.
42
Supply A start and supply B start (For cartridge
version only)
Selecting each of these buttons enables starting supply
cartridges.
3A7526B