Automatic Screen 4 - Graco PR-X Setup - Operation - Repair

Fixed ratio system
Table of Contents

Advertisement

NOTE: The information below is exclusive to the
Profinet communication mode.
Disp vol: Dispense volume during current shot. The
value from the PR-X control box is an integer and
must be multiplied by 0.01 to calculate the
requested volume. The unit is cc.
Disp rate: Dispense flow rate. The value from the
PR-X control box is an integer and must be
multiplied by 0.001 to calculate the requested
volume. The unit is cc/s.
Disp press A: Current working pressure value of
part A. The value from the PR-X control box is an
integer and the unit is psi.
Disp press B: Current working pressure value of
part B. The value from the PR-X control box is an
integer and the unit is psi.
MTR torque: Current driver motor working torque.
The value is an integer and must be multiplied by
0.001 to calculate the requested volume. The unit is
NM.
Vol ratio: Current dispense mixing ratio. The value is
an integer and must be multiplied by 0.01 to
calculate the requested volume.
3A7526B
HMI Display Operation and Identification

Automatic Screen 4

F
. 13 Automatic Screen 4
IG
On the Automatic Screen 4, press 'F1' or select the
button to display the Automatic Screen 3. Press 'F4' or
select the
button to display the Automatic Screen 5.
This screen shows the error history. It will record the
error number, time, date and explanation text for the last
50 system errors.
25