Automatic Screen 6 (For Cartridge Version Only)27 - Graco PR-X Setup - Operation - Repair

Fixed ratio system
Table of Contents

Advertisement

Automatic Screen 6 (For
Cartridge Version Only)
F
. 15 Automatic Screen 5
IG
On the Automatic Screen 6, press 'F1' or select the
button to display the Automatic Screen 5. Press 'F4' or
select the
button to return to the Automatic Screen
1.
The content and functions of this screen are as follows:
Part A and Part B supply status
To show the supply status of Part A and part B.
3A7526B
HMI Display Operation and Identification
Supply system operation
Part A or B feed: Activate to start or stop supply
device A or B, regardless of supply type (supply
pump feed or cartridge feed).
Part A or B smart feed: Only activate to drive supply
device in reloading.
-
For supply pump feed, the system will start the
pump only while reloading.
-
For cartridge feed, the piston is only active in
reloading. When the system is dispensing, the
piston is in a neutral position.
To prevent injury from moving parts, make sure the
cartridge change is completed before pressing 'F3' to
resume feed.
Cart change: Only activate to change cartridge after
the job is finished. Select 'Cart Change" to move
back the cartridge cylinder rod. Press 'F3' to move
forward the cartridge cylinder rod.
.