Using SNMP
No. Trap Name
53
httpServerDoSAttackTrap
httpConnectionStats—The number of HTTP connection attempts over the past 15 seconds.
54
alaStackMgrDuplicateRoleTrap
alaStackMgrSlotNINumber—Numbers allocated for the stack NIs as follows:
- 0: invalid slot number
- 1..8: valid and assigned slot numbers corresponding to values from the entPhysicalTable
- 1001..1008: switches operating in pass through mode
- 255: unassigned slot number.
alaStackMgrChasRole—The current role of the chassis as follows:
- unassigned(0),
- primary(1),
- secondary(2),
- idle(3),
- standalone(4),
- passthrough(5).
Note: This trap is not supported on OmniSwitch 9000 switches.
55
alaStackMgrClearedSlotTrap
alaStackMgrSlotNINumber—Numbers allocated for the stack NIs as follows:
- 0: invalid slot number
- 1..8: valid and assigned slot numbers corresponding to values from the entPhysicalTable
- 1001..1008: switches operating in pass through mode
- 255: unassigned slot number.
Note: This trap is not supported on OmniSwitch 9000 switches.
56
alaStackMgrOutOfSlotsTrap
Note: This trap is not supported on OmniSwitch 9000 switches.
OmniSwitch AOS Release 6 Switch Management Guide
Objects
Family
httpConnection-
webmgt
Stats
httpsConnec-
tionStats
alaStack-
chassis
MgrSlotNI-
Number
alaStackMgr-
ChasRole
alaStack-
chassis
MgrSlotNI-
Number
N/A
chassis
September 2009
SNMP Overview
Description
This trap is sent to management
station(s) when the HTTP server
is under Denial of Service attack.
The HTTP and HTTPS connec-
tions are sampled at a 15 second
interval. This trap is sent every 1
minute while the HTTP server
detects it is under attack.
The element identified by
alaStackMgrSlotNINumber
detected the presence of two ele-
ments with the same primary or
secondary role as specified by
alaStackMgrChasRole on the
stack.
The element identified by
alaStackMgrSlotNINumber will
enter the pass through mode
because its operational slot was
cleared with immediate effect.
One element of the stack will
enter the pass through mode
because there are no slot num-
bers available to be assigned to
this element.