Installation

The TS800 is NOT intrinsically safe. Do not install or use the
pump in an environment exposed to atmospheric agents (rain,
snow, ice), dust, aggressive gases, or in explosive environ-
ments or those with a high fire risk.
During operation, the following environmental conditions must
be respected:
Temperature:
+5 °C to +40 °C (41 °F to 104 °F)
Relative humidity:
0 to 95% (non-condensing)
Connect the pump to the power supply using an IEC-320 style
power cord of at least 10 A capacity (see Table 1 on page 27).
CAUTION
When installing the vacuum pump it is rec-
ommended that the pump be positioned in
a way that the power switch and power
cord connection remain easily accessible
to the user in order to be available as an
option to disconnect power to the pump
quickly if needed.

Use

In order to reach maximum vacuum, the pump must be left
running for at least an hour with the inlet sealed.
There are no special instructions for starting the pump; it need
only be switched on using the On/Off switch.
The optional inlet valve will open 30 seconds after the pump is
started.
WARNING
The pump is designed for operation with
neutral or noncorrosive fluids. It
is absolutely forbidden to use it with
potentially explosive or inflammable sub-
stances.
There are no special instructions for stopping the pump; it need
only be disconnected from the electric power source by the
On/Off switch.
The optional inlet valve will close immediately after the pump
is stopped.

Maintenance

Personnel responsible for pump operation and maintenance
must be well-trained and aware of the accident prevention
rules.
WARNING
Death may result from contact with
high voltages. Always take extreme care
and observe the accident prevention regu-
lations in force.
When machine is powered up,
be careful of moving parts and high volt-
ages.
If you have to perform maintenance on
the pump after a considerable time in
operation, allow it to cool as the tempera-
ture of the outer surface may be in excess
of 60 °C.
Always disconnect your power supply
to the pump before beginning maintenance
work.
NOTE
Before returning the pump to the factory
for repair, the "Request for Return" sheet
attached to this instruction manual must
be completed and sent to the local sales
office. A copy of the sheet must be inserted
in the pump package before shipping.
If a pump is to be discarded, it must be disposed of in accor-
dance with specific national standards.
Disposal
Meaning of the WEEE logo found in labels.
The following symbol is applied in accordance with the EC
WEEE (Waste Electrical and Electronic Equipment) Directive.
This symbol (valid only in countries of the European Commu-
nity) indicates that the product it applies to must NOT be dis-
posed of together with ordinary domestic or industrial waste
but must be sent to a differentiated waste collection system.
The end user is therefore invited to contact the supplier of the
device, whether the Parent Company or a retailer, to initiate the
collection and disposal process after checking the contractual
terms and conditions of sale.
For more information refer to: http://www.agilent.com/ envi-
ronment/ product/ index.shtml.
3