INSTALLATION AND
OPERATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Agilent Technologies TriScroll 300

  • Page 1 Vacuum Products Division TriScroll INSTALLATION AND OPERATION MANUAL Inverter Dry Scroll Vacuum Pump Manual No. 699904355 Revision C October 2009...
  • Page 2 ™ TriScroll 300 Inverter Dry Scroll Vacuum Pump TriScroll is a trademark of Agilent, Inc. Copyright 2009 Agilent, Inc.
  • Page 3: Table Of Contents

    TriScroll 300 Inverter Vacuum Pump Table of Contents Declaration of Conformity Warranty ..............viii Warranty Replacement and Adjustment....viii Instructions for Use ............. 1 General Information ..........1 Storage ..............1 Unpacking and Inspection........1 Installation Requirements ......... 2 Safety ..............2 Operation..............
  • Page 4 TriScroll 300 Inverter Vacuum Pump This page intentionally left blank.
  • Page 5 Pumping Speed Curves ....6 Circuit Breaker Requirements......3 TriScroll 300 Inverter Vacuum Pump ..7 Specifications ..........5 Inverter Interface .
  • Page 6: Triscroll 300 Inverter Vacuum Pump

    TriScroll 300 Inverter Vacuum Pump This page intentionally left blank.
  • Page 7: Declaration Of Conformity

    Declaration of Conformity Declaration of Conformity Konformitätserklärung Déclaration de Conformité Declaración de Conformidad Verklaring de Overeenstemming Dichiarazione di Conformità Agilent, Inc. Nous 121 Hartwell Avenue Nosotros Lexington, MA, 02421-3133 USA declare under our sole responsibility that the product, erklären, in alleniniger Verantwortung, daß dieses Produkt, déclarons sous notre seule responsabilité...
  • Page 8: Warranty

    TriScroll 300 Inverter Vacuum Pump Warranty Products manufactured by Seller are warranted against Warranty Replacement and Adjustment defects in materials and workmanship for twelve (12) All claims under warranty must be made promptly after months from date of shipment thereof to Customer, and occurrence of circumstances giving rise thereto, and must Seller’s liability under valid warranty claims is limited, at...
  • Page 9: Instructions For Use

    The TriScroll 300 weighs 26 kg WARNING (57 lbs). To avoid injury, use proper The caution messages are displayed CAUTION...
  • Page 10: Installation Requirements

    TriScroll 300 Inverter Vacuum Pump Installation Requirements Although the pump can pump trace CAUTION particulates normally found in the atmosphere, it is not designed for Safety process solids, chemicals, powders, solvents, condensates, or other par- Do not remove or modify any safety or insulating ticulates.
  • Page 11 TriScroll 300 Inverter Vacuum Pump Power Cord Check with a qualified electrician or WARNING Several power cord options are available from your serviceman if the grounding instructions Agilent dealer. Descriptions of the available power cords are not completely understood, or if and their ordering numbers are given in Table 1.
  • Page 12: Operation

    TriScroll 300 Inverter Vacuum Pump Operation Maintenance In order to reach ultimate vacuum, the pump must be left Personnel responsible pump operation running for about one hour with the inlet sealed. maintenance must be well-trained and aware of the accident prevention rules.
  • Page 13: Technical Information

    TriScroll 300 Inverter Vacuum Pump Technical Information Table 3 Specifications Model TriScroll™ 300 Inverter Dry Scroll Vacuum Pump (PTS03001INV) Interface dimensions See Figure 1 on page 6 Peak pumping speed 250 l/m, 15m /hr (8.9 cfm) See Figure 2 Media Clean air.
  • Page 14: Interface Drawing With Dimensions

    TriScroll 300 Inverter Vacuum Pump Figure 1 Interface Drawing with Dimensions Figure 2 Pumping Speed Curves...
  • Page 15: Inverter Interface

    Frame Screws; M6 (4) Gas Ballast Port (1/4" National Pipe Thread) 10. Mounting Holes; 11 mm diameter thru (8) 11. Rubber Feet (4) Figure 3 TriScroll 300 Inverter Vacuum Pump 1. Power Connector (IEC 320) 2. On/Off Switch 3. Serial Port J2 4.
  • Page 16: Pump Electrical Controller

    TriScroll 300 Inverter Vacuum Pump Pump Electrical Controller The pump is powered by an inverter that converts single phase line power into 3-phase power that drives an induction motor at a user selectable frequency. Several operational variables are modifiable through the J2 serial port when using Agilent T-Plus software.
  • Page 17: Technical Specifications

    TriScroll 300 Inverter Vacuum Pump Technical Specifications Table 4 P1 Interlock Input voltage: 200 -240 V/100-120 V*, SIGNAL NAME IN/OUT 50 - 60 Hz * Inverter with P/N S4897001 only Max frequency: 65 Hz, factory set @ 62Hz Groundout Normal Operation maximum power: 750 W...
  • Page 18: Serial Interface Specification Rs485 And Rs232

    TriScroll 300 Inverter Vacuum Pump Serial Interface Specification RS485 and Table 6 T-Plus Software Variables RS232 TYPE DESCRIPTION Table 5 J2 - Serial Port Logical Start/Stop SIGNAL NAME (1=START; 0=STOP) Logical Low Speed + 5 V out [0=OFF / 1=ON]...
  • Page 19: T+ Pumps List

    TriScroll 300 Inverter Vacuum Pump Table 6 T-Plus Software Variables (Continued) Table 7 Status LEDs TYPE DESCRIPTION LED STATUS CONTROLLER STATUS Numerical Error Code: Stop Bit 7: motor block Green flashing Ramp or Autotuning Bit 6: short circuit Bit 5: undervoltage...
  • Page 20: Bearing Purge

    TriScroll 300 Inverter Vacuum Pump 6. Open the Speed Settings directory, and click Target Gas Ballast Frequency. The pump incorporates an automatic gas ballast to prevent water and other condensates from accumulating within the pump. The standard configuration is a sintered filter installed in the 1/4"...
  • Page 21: Isolation Valve Position

    TriScroll 300 Inverter Vacuum Pump When used with the TriScroll inverter pump, the VPI Use the provided VPI valve kit only NOTE Valve status is controlled by motor operation. The VPI with Agilent TriScroll inverter pumps Valve: using inverters with part numbers Opens when the pump is running and S4896001Z and/or S4897001.
  • Page 22: Ct-100 Speed Control Kit

    TriScroll 300 Inverter Vacuum Pump CT-100 Speed Control Kit Below the lower set point value (SP2), the scroll is driven at minimum speed**. Agilent offers an optional speed control kit (P/N#: Higher than set point 2, but lower than set point...
  • Page 23: Vpi And Ct100 Speed Control Kit

    TriScroll 300 Inverter Vacuum Pump VPI and CT100 Speed Control Kit Agilent’s combination VPI and CT100 speed control kit (Agilent P/N PTSCNTRLKIT3 for NW25 and PTSCNTRLKIT4 for NW40), consists of the CT-100 Active Rough Vacuum Gauge, Communication Cable, 24 VDC Power Supply, Power Splitter Cord, Tee, Centering Ring(s), Clamp(s), and a VPI valve (Figure 10).
  • Page 24: Exhaust Silencer Kit

    TriScroll 300 Inverter Vacuum Pump Exhaust Silencer Kit Vibration Isolation Kit In certain applications it is desired to lower the noise A set of vibration isolation mounts (P/N PTSVIBISOKIT, level emitted by the pump. For these cases, Agilent offers Manual P/N: 699904385) are available for Agilent scroll Exhaust Silencer Kits (P/N EXSLRTRISCROLL, Manual pumps.
  • Page 25: Troubleshooting

    TriScroll 300 Inverter Vacuum Pump Troubleshooting Table 8 contains a list of possible problems, their probable causes, and corrective actions. Table 8 Troubleshooting Chart Problem Probable Cause Corrective Action Pump won’t start P1 interlock missing Plug in connector (provided). Wrong input voltage...
  • Page 26: Maintenance

    Maintenance General Information Agilent TriScroll 300 Inverter pumps are designed to provide years of trouble-free service if maintenance procedures and intervals are observed. Bearing grease replenishment and tip seal replacement is recommended when pump base pressure has risen to an unacceptably high level for your application. Bearings, rotary seals and o-rings should also be replaced if the pump exhibits humming or grinding noises from the bearings.
  • Page 27: Maintenance And Tooling Kits

    Major Maintenance Kit All bearings, bearing seals, bearing All TriScroll 300 Series models PTSS0300MK lubricant, O-rings, and tip seals required to rebuild TriScroll 300 series pumps. Maintenance Tool Kit All fixtures and tools required to perform All TriScroll 300 Series models PTSS0300TK any maintenance on TriScroll 300 Series pumps.
  • Page 28: Factory Service Options

    PTS0300KMA Accessories The accessories listed in Table 12 are available for use with the TriScroll 300 Inverter pump. Contact your local Agilent office to place an order. A list of offices is included on the rear cover of this manual.
  • Page 29 Please follow these instructions whenever one of our products needs to be returned. 1) Complete the attached Request for Return form and send it to Agilent Technologies (see below), taking particular care to identify all products that have pumped or been exposed to any toxic or hazardous materials.
  • Page 30 This page intentionally left blank. 4) HEALTH and SAFETY CERTIFICATION AGILENT TECHNOLOGIES CANNOT ACCEPT ANY PRODUCTS CONTAMINATED WITH BIOLOGICAL OR EXPLOSIVE HAZARDS, RADIOACTIVE MATERIAL, OR MERCURY AT ITS FACILITY. Call Agilent Technologies to discuss alternatives if this requirement presents a problem.
  • Page 31 Shipping Regulations (IATA, DOT, etc.) and carrier requirements. Customers receiving an Advance Exchange product agree to return the defective, rebuildable part to Agilent Technologies within 15 business days. Failure to do so, or returning a non-rebuildable part (crashed), will result in an invoice for the non-returned/non-rebuildable part.
  • Page 32 TriScroll 300 Inverter Vacuum Pump This page intentionally left blank.
  • Page 34 Agilent Technologies Vacuum Product Division United States & Canada India Southeast Asia Agilent Technologies Agilent Technologies Agilent Technologies Vacuum Products Division Vacuum Product Division Vacuum Products Division 121 Hartwell Avenue 205-A, “A” wing of Galleria, South East Asia (SEA) - Alex Ho...

This manual is also suitable for:

Triscroll 600Pts03001invPss06001inv

Table of Contents