Dimplex VFE 20 Installation And Operating Instructions Manual page 46

Storage heater
Table of Contents

Advertisement

Available languages

Available languages

English
Selecting the DC control signal
Use the
keys to select DC. Display flashes.
Press the ENTER key. Setting is complete.
Selecting the AC control signal
Use the
keys to select AC. Display flashes.
Press the ENTER key. Display 80 flashes.
NOTE
Display AC 80 stands for the maximum control signal
duty cycle (duty cycle signal) of the central control de-
vice.
In special cases, e.g. extremely old systems, the duty
cycle signal may need to be adjusted.
If necessary, adjust the duty cycle signal with the
keys.
Press the ENTER key. Setting is complete.
EN-20
P10 - operation with external room temperature
controller
NOTE
The device has an integrated room temperature con-
troller with week program. But if the device is to be
controlled via an external controller, program P10
must be set to ON.
Call up the installer menu.
Confirm the PIN code four times with the ENTER
key. Display P9 flashes.
Use the
Press the ENTER key. OFF flashes.
Use the
Press the ENTER key. Setting is complete.
2007/A
Commissioning
keys to select P10. Display flashes.
keys to select ON. ON flashes.
www.dimplex.eu