7.7 Mount the tilt protection.
NOTE
The device must be secured so that it does not tilt.
After assembly, the upper edge of the storage heater
must be able to withstand a horizontal load of at least
200N (20 kg) without tilting or shifting.
If the required stability can not be achieved with the
supplied accessories, e.g. if the wall is not sufficiently
stable, the installer must use a more suitable method
for securing the heating device on the wall.
NOTE
Ensure that the indentations in the storage stones for
holding the heating element always point upwards.
7.8 Push the first row of storage stones under the
heating element in the core room, starting from the
right.
NOTE
Ensure heating elements are positioned correctly in
left most position on brick grooves.
EN-16
7.9 After inserting the second row, push in the third
row of storage stones under the heating element.
7.10 After inserting the fourth row, push in the fifth
row of storage stones under the heating element.
7.11 Insert the top row of storage stones in the same
way. Check that the heating element can slide freely.
Trapped heating elements cause noises. Clean the air
outlet area and the switchbox.