Mixer – FX Shelf EQ
This screen controls and displays the settings for
the FX Channel high and low shelf equalization and
high-pass filter.
• The HPF is variable with a range of 20 Hz to
2,000 Hz. It passes frequencies above the
setting while cutting those below.
• Bands 1 and 2 are shelving filters.
1.
tab – Selects the EQ screen.
PEQ
2.
– Engages / disengages the equalizer.
PEQ Out/In
3.
RTA On
– Engages / disengages the a real time
analyzer that displays the tonal balance of the
channel's signal including peak hold indicators.
NOTE!:
Only one
RTA may be running
on the system at a
time. Touch the RTA
button. If another
device is using the
RTA, the message to the right displays.
NOTE!:
When the RTA is off, the Parametric EQ graph expands to use the entire graph area.
4.
Reset
button – Sets all the EQ controls to their factory default position.
5.
RTA
display – Displays the amplitude of the channel signal in 1/3 octave bands. Peak hold indicators are displayed for each band.
RTA
graph vertical scale – Represents audio level from -60 dB to -5 dB.
graph horizontal scale – Represents frequency from 31.5 Hz to 16 kHz.
RTA
6.
graph – A graphic representation of the equalization curve based on the EQ settings. The trace dims to indicate that the EQ is
EQ
Out (disengaged).
graph vertical scale – Represents audio level from -20 dB to +20 dB.
EQ
EQ
graph horizontal scale – Represents frequency from 20 Hz to 20 kHz.
7.
EQ
handles
Touch, hold, and drag to change the Frequency and Gain of the associated EQ band. The frequency band button must be engaged
to see the handles.
8.
High Pass
button – Engages / disengages the HPF (described above).
9.
Low Shelf and High Shelf
below the set frequency. The high shelving filter raises or lowers a range of frequencies above the set frequency.
10.
Frequency Bands 1 and 2
11.
Nain
control knob and readout – Adjusts the gain at the frequency setting of the associated EQ band. Range of -15 dB to +15 dB.
12.
Freq
control knob (Frequency bands 1 – 2) – Sets the knee frequency of the associated shelf band.
13.
Freq control knob
(High Pass) – Sets the frequency of the high pass filter as measured from a point 3 dB below 0 or unity.
TD-001578-01-C
The RTA is currently being
used by [device name]. Do
you want to assign it in-
stead to this device?
Yes
No
buttons – EQ Band 1 and Band 2 are shelving filters. The low shelving filter raises or lowers a range of frequencies
buttons – Engages / disengages the associated shelving EQ band.
Mixer
1
2
5
6
7
8
9
13
38
Touch the
Touch FX 1
USB/FX Bank
USB / FX
FX 1
3
4
10
11
12