IBM Netfinity ServeRAID-4L Ultra160 User Reference page 79

Scsi controller
Table of Contents

Advertisement

BCS
ECS
Explanation and possible recovery action
03
B8
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild, Hot-Spare/Standby Hot-Spare, and Ready/Standby drives are not responding.
Action:Press F4, F5, F7, or F10.
03
C8
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild drives are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
03
D8
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild and Hot-Spare/Standby Hot-Spare drives are not responding and unidentified
drives were found.
Action:Press F4, F5, F7, or F10.
03
E8
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild and Ready/Standby drives are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
03
F8
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild, Hot-Spare/Standby Hot-Spare, and Ready/Standby drives are not responding
and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
07
00
Explanation:The specified drive is not responding.
Action: To correct the problem:
1. If the specified physical drive is in an external enclosure, check to make sure the enclosure
is powered on. If the enclosure is not powered on, turn on the power and press F4 to retry.
2. Download and install the latest version of IBM ServeRAID software. See "Obtaining
ServeRAID updates" on page 21 for more information.
3. Replace the failed physical drive.
07
08
Explanation:The specified drives are not responding.
Action: To correct the problem:
1. If the specified physical drives are in an external enclosure, check to make sure the
enclosure is powered on. If the enclosure is not powered on, turn on the power and press F4
to retry.
2. Download and install the latest version of IBM ServeRAID software. See "Obtaining
ServeRAID updates" on page 21 for more information.
3. Replace the failed physical drives.
07
0C
Explanation:Online/Rebuild drives are not responding, and a drive was found at the incorrect
SCSI ID.
Action:Press F4, F5, F6, or F10.
07
18
Explanation:Online/Rebuild and Hot-Spare/Standby Hot-Spare drives are not responding.
Action:Press F4, F5, or F10.
07
1C
Explanation:Online/Rebuild and Hot Spare/Standby Hot-Spare drives are not responding, and a
drive was found at the incorrect SCSI ID.
Action:Press F4, F5, F6, or F10.
07
28
Explanation:Online/Rebuild and Ready/Standby drives are not responding.
Action:Press F4, F5, or F10.
Chapter 9. Solving ServeRAID problems
65

Advertisement

Table of Contents
loading

Table of Contents