Error: Cannot
The ServeRAID controller was
disable this
unable to prevent an extra copy of
controller BIOS.
its BIOS code from being stored on
the server. This condition occurs
when the server contains multiple
ServeRAID controllers.
Installation
The server cannot access the
stopped.
ServeRAID controller.
New controller
When the ServeRAID controller
installed in a
detects that the identifiers of the
configured server
drives do not match the controller
or drives are
configuration information, the
imported.
following message appears:
x Online drive(s) found with
mismatch configuration
Examples of possible messages:
Configuration mismatch Channel
1 SCSI ID 0 with Host ID
Configuration mismatch Channel
2 SCSI ID 0 with Host ID
®
®
60
IBM
Netfinity
: ServeRAID
-4L Ultra160 SCSI Controller User's Reference
Action
Have the server serviced.
This is a follow-on message to a preceding message. Follow
the Action instructions for the preceding message to resolve
the problem.
Press one of the following keys:
F2
Detailed description. Press this key for a detailed
description of the problem, such as the example
messages above.
F4
Retry. Press this key after correcting the problem.
For example, press F4 after you move the physical
drive to its previously assigned location, or after you
install the original physical drives back in the server.
F5
Change the configuration and set the drive to
defunct. Press this key to accept the new state that
the ServeRAID controller will assign to the drive.
For example, the ServeRAID controller will assign
the drive a state of defunct or empty.
Note: A physical drive in the defunct state does not
necessarily mean that you need to replace the
drive. Before you replace the drive, ensure that:
1. All cables are connected properly to the
backplane or system board, and to the physical
drive. Also, ensure that all cables inside the
server are connected properly.
2. The hot-swap drive trays are seated properly in
the drive bay.
3. If multiple drives fail in separate arrays (one
physical drive per array), then replace each of
the defunct physical drives. If multiple physical
drives fail at the same time within the same
array, contact your IBM service representative.
See "Rebuilding a defunct drive" on page 68 for
more information.
After you perform these steps, if the physical drive
does not function properly, replace the drive.