IBM Netfinity ServeRAID-4L Ultra160 User Reference page 78

Scsi controller
Table of Contents

Advertisement

BCS
ECS
Explanation and possible recovery action
00
02
Explanation:Invalid NVRAM configuration.
Action:Start the IBM ServeRAID Support CD and follow the instructions that appear on the
screen.
If no instructions appear or if the problem persists, have the server serviced.
00
03
Explanation:Invalid flash and NVRAM configuration.
Action:Start the IBM ServeRAID Support CD and follow the instructions that appear on the
screen.
If no instructions appear or if the problem persists, have the server serviced.
01
08
Explanation:No configuration was found in drives, or Online/Rebuild drives are not responding.
Action:Press F4, F5, F7, or F10.
01
18
Explanation:No configuration was found in drives, or Online/Rebuild and Hot-Spare/Standby
Hot-Spare drives are not responding.
Action:Press F4, F5, F7, or F10.
01
28
Explanation:No configuration was found in drives, or Online/Rebuild and Ready/Standby drives
are not responding.
Action:Press F4, F5, F7, or F10.
01
38
Explanation:No configuration was found in drives, or Online/Rebuild, Hot-Spare/Standby
Hot-Spare, and Ready/Standby drives are not responding.
Action:Press F4, F5, F7, or F10.
01
48
Explanation:No configuration was found in drives, or Online/Rebuild drives are not responding
and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
01
58
Explanation:No configuration was found in drives, or Online/Rebuild and Hot-Spare/Standby
Hot-Spare drives are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
01
68
Explanation:No configuration was found in drives, or Online/Rebuild and Ready/Standby drives
are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
01
78
Explanation:No configuration was found in drives, or Online/Rebuild, Hot-Spare/Standby
Hot-Spare, and Ready/Standby drives are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
03
88
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild drives are not responding.
Action:Press F4, F5, F7, or F10.
03
98
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild and Hot Spare/Standby Hot-Spare drives are not responding.
Action:Press F4, F5, F7, or F10.
03
A8
Explanation:A drive was imported from another server and it has valid configuration, and
Online/Rebuild and Ready/Standby drives are not responding.
Action:Press F4, F5, F7, or F10.
®
®
64
IBM
Netfinity
: ServeRAID
-4L Ultra160 SCSI Controller User's Reference