Message
Explanation
Configured drives
When the ServeRAID controller
are not in the
detects that a previously configured
configured
drive is present, but the drive is in
location.
a new location, the following
message appears:
x Online drive has been rearranged
where x is the number of drives
that have been rearranged.
For example:
Examples of possible messages
are:
Online Drive on Channel 3 SCSI
ID 4 moved to Channel 3 SCSI
ID 3
Online Drive on Channel 3 SCSI
ID 3 moved to Channel 3 SCSI
ID 4
Controller is not
The ServeRAID controller is not
responding to
operational.
commands. No
logical drives are
installed.
Action
Press one of the following keys:
F2
Detailed description. Press this key for a detailed
description of the problem, such as the example
messages above.
F4
Retry. Press this key after correcting a problem. For
example, press F4 after you move the physical drive
to its previously assigned location.
F5
Change the configuration and set the drive to
defunct. Press this key to accept the new state that
the ServeRAID controller will assign to the drive.
For example, the ServeRAID controller will assign
the drive a state of defunct or empty.
Note: A physical drive in the defunct state does not
necessarily mean that you need to replace the
drive. Before you replace the drive, ensure that:
1. All cables are connected properly to the
backplane and to the physical drive. Also,
ensure that all cables inside the server are
connected properly.
2. The hot-swap drive trays are seated properly in
the drive bay.
3. If multiple drives fail in separate arrays (one
physical drive per array), then replace each of
the defunct physical drives. If multiple physical
drives fail at the same time within the same
array, contact your IBM service representative.
See "Rebuilding a defunct drive" on page 68 for
more information.
After you perform these steps, if the physical drive
does not function properly, replace the drive.
F6
Change the configuration and accept the
rearrangement. Press this key to change the
configuration to match the current drive location.
You might remove the hot-swap drives from the
server for security or maintenance reasons. If you
replace the drives but install them in different drive
bays, you can press F6 to accept the new locations,
and the ServeRAID controller will update the
configuration.
F10
Continue startup without changing the configuration.
Press this key to continue without change to the
configuration.
Have the server serviced.