7.7.2 Adjusting the operating pressure

Proper setting
Refer to the Technical Data ( p. 119) chapter for the permissible
operating pressure. The operating pressure cannot deviate by more than
± 0.5 bar.
Fig. 72: Adjusting the operating pressure
(1) - Pressure regulator
To adjust the operating pressure:
1. Pull the pressure regulator (1) up.
2. Turn the pressure regulator until the pressure gage (2) indicates the
3. Push the pressure regulator (1) down.
104
NOTICE
Property damage from incorrect operating pressure!
Incorrect operating pressure can result in damage to the machine.
Ensure that the machine is only used when the operating pressure
is set correctly.
proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
(2) - Pressure gage