Using State Overview, State Histogram, And Time Interval - HP 1660CP Series User Manual

Logic analyzers
Hide thumbs Also See for HP 1660CP Series:
Table of Contents

Advertisement

Using State Overview, State Histogram, and Time Interval

Using State Overview, State Histogram, and Time
Interval
This section explains how to select the display fields, set up the logic
analyzer and use the State Overview, State Histogram and Time Interval
modes of SPA.
Setting up the logic analyzer
This section assumes you have defined the Format and have connected the
logic analyzer probes to the target system. For complete details on these
topics, refer to the appropriate reference section for your analyzer.
For a detailed description of State Overview, State Histogram, and Time
Interval mode measurement processes, refer to the previous section, "SPA
measurement processes."
Using State Overview mode
Choosing a label to monitor To specify a label to monitor, select the
"Label" field in the State Overview menu (item 1 in the figure on the next
page). The pop-up shows a list of all the labels defined in the Format
Specification. From this list, choose the label you want to monitor.
Changing from one label to another will erase the display setup for the first
label. If you want to change to a different label, but don't want to lose the setup
for the current one, first save the current one to disk or print it.
System Performance Analysis (SPA) Software
9-21

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Hp 1660cpHp 1661cpHp 1662cpHp 1663cp

Table of Contents