Specifying a Basic Trigger

The default analyzer triggers are
While storing "anystate" TRIGGER on "a" 1 time
Store "anystate"
for state analyzers and
TRIGGER on "a" > 8 ns
for timing analyzers. If you want to simply record data, these will get
you started. They can quickly be tailored by specifying a particular
pattern to look for instead of the general case.
Customizing a trigger generally requires these steps:
Assign terms to both analyzers.
Define the terms.
Change the trigger to use the new terms.
4–3