Pentair Pentek Intellidrive PID10 Installation And Operation Manual page 16

Hide thumbs Also See for Pentek Intellidrive PID10:
Table of Contents

Advertisement

Available languages

Available languages

I/O CONNECTIONS
Label
AI+
Positive connection for transducer
AI-
Negative connection for transducer
Positive side of 24 volt power supply. Used to power
V+
external devices.
Negative side of 24 volt power supply. Used to power
V-
external devices.
Positive connection of Digital Input 1. Connect when
I1+
using an external device to control Intellidrive.
Negative connection of Digital Input 1. Connect when
I1-
using an external device to control Intellidrive.
Positive connection of Digital Input 2. Connect when
I2+
using an external device to control Intellidrive.
Negative connection of Digital Input 2. Connect when
I2-
using an external device to control Intellidrive.
Output relay (dry contacts) connection. Programmed
O1+
to close when pump is Running or Faulted.
Output relay (dry contacts) connection. Programmed
O1+
to close when pump is Running or Faulted.
Positive connection of an RS-485 communication
P
device (see Figure 19).
Negative connection of an RS-485 communication
N
device (see Figure 19).
16
Function
Red transducer wire
Black transducer wire
Positive side of 24V external device, i.e., flow switch, moisture
sensor, alternator, etc. Need to complete the circuit with V-. See
Figures 15 and 17.
Typically to I1-, I2-, or O1+. Used with a flow switch, moisture
sensor, alternator, etc. Need to complete the circuit with V+. See
Figures 15 and 17.
From an external device i.e., flow switch, moisture sensor,
alternator, etc. Requires complete circuit connection with I1-.
See Figures 15 and 16.
Can be from V- or from the negative side of an external power
supply. Requires complete circuit connection with I1+. See
Figures 15 and 16.
From an external device, i.e., flow switch, moisture sensor,
alternator, etc. Requires complete circuit connection with I2-.
See Figures 15 and 16.
Can be from V- or from the negative side of an external power
supply. Requires complete circuit connection with I2+. See
Figures 15 and 16.
Positive wires of an external device. See Figures 17 and 18.
Positive wires of an external device. See Figures 17 and 18.
Positive wire from RS-485 device.
Negative wire from RS-485 device.
Table 6 - I/O Functions, Connections, Ratings
Connection
Rating
24 Volt (supplied)
24 Volt (supplied)
40mA maximum output
40mA maximum output
Accepts 24VDC and up to
230VAC
Accepts 24VDC and up to
230VAC
Accepts 24VDC and up to
230VAC
Accepts 24VDC and up to
230VAC
Accepts up to 5 Amps at
24VDC and 8 Amps at up
to 230VAC
*Only non-inductive
loads
Per RS-485 Standard
Per RS-485 Standard
PN957 (25-06-20)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents