INSTRUCTIONS
OPERATION
OPERATIONAL
As the workday progresses, operators should regularly inspect the strainers to
ensure they have not become clogged. If the strainers become clogged, it will
INSPECTION
reduce the washing capability of the machine.
SHUTDOWN &
1. Turn machine off by pushing ON/OFF button.
2. Remove drain stopper and allow tub to drain.
CLEANING
3. Remove and clean the strainers.
!
CAUTION
CAUTION! Do NOT beat
strainers to remove
soil and debris!
4. Unscrew wash/rinse arm from its manifold.
5. Verify nozzles and arm are free from obstruction. If clogged, remove end-caps,
clean nozzles with a brush, and flush with fresh water.
6. Replace end-caps and tighten with screwdriver.
7. Spray or wipe out interior of machine.
8. Replace wash/rinse arm.
9. Ensure all strainers are clean and securely in place.
10. Replace drain stopper.
11. Use stainless steel polish to protect outside of machine.
07610-003-37-08-L