Semi-Permanent Wall Installation; Condensate Drainage; Internal Condensate Tank; Fixed Condensate Drainage Hose - Rinnai RPC26MC Operation & Installation Manual

Portable room air conditioner
Table of Contents

Advertisement

SEMI-PERMANENTWALLINSTALLATION
In  some  cases  a  window  opening  might  not  be  assessable;  therefore  Wall  Exhaust Adaptor  and  Wall  Exhaust 
Terminal are required that can be connected the Exhaust Duct.  Note: Wall Exhaust Adaptor (PN 94320029) and 
Wall Exhaust Terminal (PN 94320031) are not supplied, please order separately.
Thepositioningandinstallationofthewallflangeshouldbecompletedbyanauthorisedperson
andmustcomplywithallmunicipalbuildingcodesandOH&Sguidelines.
WARNING

CONDENSATE DRAINAGE

CondensateproducedbythisapplianceisNOTpotable,
disposeofviawasteoutletorallowtoevaporate.
NOTE

INTERNAL CONDENSATE TANK

During operation the appliance may produce small amounts of condensate. 
The  appliance  has  an  inbuilt  condensate  tank.  If  all  three  drain  outlets 
(7), (8) and (12) are plugged, then this tank may reach capacity. If this 
happens, the appliance will stop operation and the condensate full code 
"P1" will be shown on the control panel display and the condensate tank 
will need to be drained before operation can be resumed. To do this:
1�
Place shallow tray such as an oven baking tray or similar (with at 
least a 1 litre volume) under Drain Tray Outlet (12).
2�
Remove  the  plug  from  Drain  Tray  Outlet  (12)  and  drain  out  the 
condensate water, once the condensate is drained replace the plug, 
the appliance will now be able to then resume operation.

FIXED CONDENSATE DRAINAGE HOSE

As an alternative to using the appliances internal condensate tank, a condensate drain hose (18) may de fitted.
7
8
Option 1 - External Drain Tray: with drain outlets (8) and (12) plugged, fit the condensate drain hose (18) to drain 
outlet (7) and drain the condensate into a drain tray.
Option 2 - Existing Waste Outlet: with drain outlets (7) and (8) plugged, fit the condensate drain hose (18) to drain 
outlet (12) and drain the condensate into a drain tray or waste outlet.
ThepointtowhichthecondensateistobedrainedMUST BElowerthanthedrainageoutletpoint.
Whenusingadraintrayoption,ensurethatthecapacityofthetrayisgreaterthanthatofthe
NOTE
condensatebeingproduced.
Rinnai
Option
7
1
12
8
21
INSTALLATION
7
8
Shallow baking tray
Portable Room AC OIM
12
Option
2
12