Daikin SkyAir RZR-P Series Engineering Data page 174

Cooling only 60hz, heat pump 60hz, r-410a, inverter
Hide thumbs Also See for SkyAir RZR-P Series:
Table of Contents

Advertisement

EDUS281120_a
(4)
Remove the front panel and the service lid. (Refer to Fig. 5)
< How to remove the front panel and service lid >
(1) Open the front panel to the point where it stops.
(2) Push the axes on either side of the front panel towards the center of the main unit and remove. (You
can also remove it by sliding the front panel either to the left or right and pulling it forward.)
(3) Remove the screw from the service lid and pull the handle forward.
(5)
Point the pipe in the direction it will be passed out.
For bottom-right and back-right piping (Refer to Fig. 6)
Wrap the drain hose and the refrigerant piping together with the insu-
lating tape (4) so that the drain hose is below the refrigerant piping.
For left, bottom-left, and back-left piping
Remove the front grill . (Refer to Fig. 7)
< How to remove the front grill >
Remove the front grill as described below when securing the indoor
unit with screws or when attaching Optional Accessories (wireless
remote controller, adapter PC board, etc.).
(1) Remove the front panel.
(2) Remove the screws (3 places) securing the front grill .
(3) Remove the tabs (3 places) securing the front grill by pushing them in the direction of the arrows.
(4) Making sure not to catch the horizontal fl aps, remove the front grill by pulling in the direction of the arrow
(3)
English
RZR-P, RZQ-P(9)
Axis
Tab position
(3)
Screw position
(2)
(2)
Screw position
Front panel
Axis
(1)
Axis
(2)
Fig. 5
Tab position
(3)
Front grill
(2)
Fig. 7
Installation of indoor unit
Service lid
(2)
(3)
Handle
Screw
Insulating tape (4)
Refrigerant piping
Drain hose
Fig. 6
Tab
(4)
8
3PN07521-2C
173