Specifications
Ceiling suspended type, continued
Indoor unit
Model
Outdoor unit
Power supply
1, 2
Cooling capacity
SEER (Rated)
EER (Rated)
Indoor unit
Color
Dimensions
H×W×D
Type
Coil
Rows×Stages×FPI
Face area
Model
Type
Fan
Motor output
Airflow rate (H/L)
Air filter
Mass (Weight)
Liquid
Piping
Gas
connections
Drain
Wired
Remote controller (option)
Wireless
Outdoor unit
Color
Dimensions
H×W×D
Type
Coil
Rows×Stages×FPI
Face area
Model
Comp.
Type
Motor output
Model
Type
Fan
Motor output
Airflow rate
Mass (Weight)
Liquid
Piping
Gas
connections
Drain
Safety devices
Capacity step
Refrigerant control
Standard length
Ref. piping
Max. length
Max. height difference
Model
Refrigerant
Charge (factory charge)
Model
Ref. oil
Charge
Drawing Number
Notes:
1. Indoor temp. : 80°FDB, 67°FWB (27°CDB /19.4°CWB) / outdoor temp. : 95°FDB (35°CDB) / Equivalent piping length : 25 ft (7.5 m), level difference : 0.
2. Capacities are net, including a deduction for cooling for indoor fan motor heat.
10
1 phase, 208/230V, 60Hz
Btu/h
Btu/h-W
White (10Y9/0.5)
in (mm)
7–11/16 × 62–5/8 × 26–3/4 (195 x 1591 x 680)
2 × 12 × 15 + 2 × 10 × 15
ft² (m²)
3.66 + 2.95 (1.1 + 0.9)
W
3
cfm (m
/min)
830/670 (24/19)
Resin net (With mold resistant)
Lbs (kg)
3/8 (9.5) (Flare connection)
in (mm)
5/8 (15.8) (Flare connection)
in (mm)
in (mm)
VP20 (External dia. 1 (25.4), Internal dia. 3/4 (19.1))
Ivory white (5Y7.5/1)
in (mm)
52–15/16 × 35–7/16 × 12–5/8 (1345 x 900 x 321)
ft² (m²)
JT100G-VDLW@T
Hermetically sealed scroll type
kW
KFD–325–70–8C2
W
3
cfm (m
/min)
Lbs (kg)
3/8 (9.5) (Flare connection)
in (mm)
5/8 (15.8) (Flare connection)
in (mm)
1 (25.4) (Hole)
in (mm)
High pressure switch.
Outdoor fan driver overload protector.
Thermal protector for indoor fan motor.
Inverter overload protector.
Fusible plugs. Fuse.
%
Electronic expansion valve
ft (m)
ft (m)
ft (m)
Lbs (kg)
Refer to the name plate of compressor.
L (oz)
FHQ36MVJU
RZR36PVJU
36,000
14.0
10.2
FHQ36MVJU
Cross fin coil
Sirocco fan
130
90 (41)
BRC1E71
BRC7E83
RZR36PVJU
Cross fin coil
2 × 60 × 13
12.2 (3.7)
2.5
Propeller Fan
70×2
3,740 (106)
283 (128)
25-100
25 (7.5)
230 (70)
164 (50)
R-410A
8.8 (4)
1.5 (51)
C: 4D071676
EDUS281120_a
FHQ42MVJU
RZR42PVJU
1 phase, 208/230V, 60Hz
40,500
13.8
9.5
FHQ42MVJU
White (10Y9/0.5)
7–11/16 × 62–5/8 × 26–3/4 (195 x 1591 x 680)
Cross fin coil
2 × 12 × 15 + 2 × 10 × 15
3.66 + 2.95 (1.1 + 0.9)
Sirocco fan
130
850/700 (24/20)
Resin net (With mold resistant)
90 (41)
3/8 (9.5) (Flare connection)
5/8 (15.8) (Flare connection)
VP20 (External dia. 1 (25.4), Internal dia. 3/4 (19.1))
BRC1E71
BRC7E83
RZR42PVJU
Ivory white (5Y7.5/1)
52–15/16 × 35–7/16 × 12–5/8 (1345 x 900 x 321)
Cross fin coil
2 × 60 × 13
12.2 (3.7)
JT100G-VDLW@T
Hermetically sealed scroll type
3.0
KFD–325–70–8C2
Propeller Fan
70×2
3,740 (106)
283 (7.5 m)
3/8 (9.5) (Flare connection)
5/8 (15.8) (Flare connection)
1 (25.4) (Hole)
High pressure switch.
Outdoor fan driver overload protector.
Thermal protector for indoor fan motor.
Inverter overload protector.
Fusible plugs. Fuse.
25-100
Electronic expansion valve
25 (7.5)
230 (70)
164 (50)
R-410A
8.8 (4)
Refer to the name plate of compressor.
1.5 (51)
C: 4D071676
RZR-P, RZQ-P(9)