Installation of indoor unit
1. When using 1 remote controller for 1 indoor unit.
(Normal operation)
Power supply
208-230V
Outdoor unit
60Hz
Control box
IN/D OUT/D
F
1
L
L
1
2
L
L
1
2
Indoor unit
2. When using 2 remote controllers for 1 indoor unit.
Power supply
208-230V
Outdoor unit
60Hz
Control box
IN/D OUT/D
F
1
F
L
L
1
2
L
L
P
1
2
Indoor unit
NOTE
1. All transmission wires except for remote controller wire are
polarized and must match the terminal symbol.
2. A single switch can be used to supply power to units on the
same system. However, branch switches and branch circuit
breakers must be selected carefully.
3. Do not ground the equipment on gas pipes, water pipes or
lightning rods, or crossground with telephones. Improper
grounding could result in electric shock.
10.
ATTACHING THE SUCTION GRILLE,
THE DECORATION PANELS AND THE
PROTECTION NET
Once wiring is complete, fi rmly attach the control box lid, the
suction grille, the decoration panels and the protection net in the
order opposite to detachment.
Attaching the protection net
Attach the protection net from the way of the hook (i), fi x 2
securing screws of the middle of the other side fi rst (ii), then
fi x the remaining securing screws (iii).
12
148
F
F
F
2
1
2
P
P
F
F
T
T
1
2
1
2
1
2
P
P
1
2
Remote controller
2
F
1
F
2
P
F
F
T
T
1
2
1
2
1
2
P
P
P
P
1
2
1
2
For use with 2 remote controllers
Hook
Hook
Protection net
securing screws (M4)
11.
FIELD SETTING
Make sure the control box lids are closed on the indoor and
outdoor units, and turn on the power.
Field setting must be made from the remote controller in
accordance with the installation manual.
Setting can be made by changing the "Mode No.", "FIRST
CODE NO.", and "SECOND CODE NO.".
For setting and operation, refer to the "FIELD SETTING" in
the installation manual of the remote controller.
11-1
Setting air fi lter sign
Remote controllers are equipped with liquid crystal display
air filer signs to display the time to clean air filters.
Change the SECOND CODE NO. according to "Table 5"
depending on the amount of dirt or dust in the room.
(SECOND CODE NO. is factory set to "01" for air fi lter con-
tamination-light.)
Table 5
Spacing time of
Setting
display air fi lter sign
(long life type)
Air fi lter contamina-
Approx. 2500 hrs
tion-light
Air fi lter contamina-
Approx. 1250 hrs
tion-heavy
<When using wireless remote controllers>
When using wireless remote controllers, wireless remote
controller address setting is necessary. Refer to the instal-
lation manual attached to the wireless remote controller for
setting instructions.
EDUS281120_a
Decoration
panel
(ii)
Protection net
(i)
(ii)
(ii)
(i)
(iii)
Fig. 29
FIRST
SECOND
Mode
CODE
CODE
No.
NO.
NO.
01
10 (20)
0
02
English
C: 3PN06240-12Q