Use a wrench to connect the fluid supply hose
between the fluid supply and the fluid inlet (F) on the
isolation cabinet. The maximum fluid pressure is 100
psi (0.7 MPa, 7.0 bar).
Note
For the system to function correctly, the inlet
fluid pressure must not exceed the inlet air
pressure.
Consider installing a manual fluid shut-off valve (FV)
close to the cabinet to easily turn off the fluid supply
during installation or service.
Connect the
the CAN
CAN Cables
Connect
Connect
the
CAN
Connect the Control Area Network (CAN) cables
to the control interface so that the interface can
communicate with the isolation system.
1. Connect the power supply CAN cable:
a. Locate the CAN cable attached to the power
supply (P) on the back of the cabinet.
b. On the right side of the cabinet, screw the
cable into the fitting labeled
Figure 14 Controller CAN Cable Connections
on the Cabinet
3A7370B
Hose to to to the
Hose
the
the
Cables
Cables
.
2. Connect the control interface CAN cable:
a. The system is equipped with another CAN
cable. Screw one end of the cable into the
fitting (43) on the right side of the cabinet.
b. The bottom of the controller contains two
fittings. Screw the other end of the cable into
the fitting (43).
Figure 15 Connections on the Control Interface
3. Insert the controller into the bracket on the top
of the cabinet.