The Home screen is the primary screen that the
operator uses while painting.
When the system is powered, it enters Off mode.
When in Off mode, the operator must first select
Standby mode for painting.
After Standby is select, the operator can select the
Prime, Purge, or Spray buttons for painting.
Run
Run Screen
Run
Enter
Enter
Enter
Press to enter a screen for editing.
Screen
Screen
Screen
Editable data on the screen is
highlighted. Use up or down arrows to
move among the data fields.
Exit
Exit
Exit
Press to exit a screen after editing.
Screen
Screen
Screen
38
Screen Key
Screen
Key
Key
Mode
Mode Key
Mode
Standby
Standby
Standby Press to put the system into Standby
mode. Standby mode is used to prepare
the system for operation or for a break
in operation, such as a shift change. All
fluid valves are closed and all air valves
are off. The isolation valve (G) is in the
down (bottom) position.
In Standby mode, the system verifies
that there is inlet air supply and that
the minimum required 70 psi (0.5 MPa,
4.8 bar) air pressure is supplied to the
system.
Prime
Prime
Prime
Press to put the system into Prime mode.
Prime mode is used to load the system
with new material. Pump volume is
minimized and air to the gun is off. The
system stays grounded.
Purge
Purge
Purge
Press to put the system into Purge mode.
Purge mode is used for flushing the
system or changing colors. The pump
fills and dispenses, but air to the gun is
off and the system stays grounded.
Spray
Spray
Spray
Press to put the system into Spray mode.
Spray mode is used for painting. As
soon as the system enters Spray mode,
the pump begins to fill.
When the gun is triggered to spray, the
isolation valve (G) and the ground rod
(N) raise to allow the system to build
voltage.
When the trigger is released, the isolation
valve (G) and the ground rod (N) lower.
The system discharges and the pump
begins to refill.
To enter Spray mode, you must first be
in either Prime or Standby mode. You
cannot enter Spray mode directly from
Purge mode.