Replace Hcm; Replace Adm; Software Update Procedure - Graco Reactor 2 H-30 Repair Parts

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Repair

Replace HCM

HCM
Replace
Replace
HCM
1. Follow
Before Beginning Repair, page
2. Open the electrical enclosure and disconnect all
cables from the HCM (603).
3. Remove the nuts (610) and HCM (603).
4. Set rotary switch.
Figure 12 Replace HCM
HCM
HCM
HCM Rotary
Rotary Switch
Rotary
Switch Positions
Switch
Positions
Positions
0 = Reactor 2, H-30
1 = Reactor 2, H-40
2 = Reactor 2, H-50
3 = Reactor 2, H-XP2
4 = Reactor 2, H-XP3
70

Replace ADM

Replace
Replace
50.
1. Loosen four screws (142) on the inside of the
electrical enclosure door. Lift up and pull out to
remove ADM (140).
2. Disconnect CAN cable (622).
3. Inspect ADM (140) for damage. Replace if
necessary.
4. Update software by installing an upgrade token
into ADM and cycling system power. Wait until
the update is complete before removing the
token and restarting the system.
Figure 13
Software Update
Software
Software
Repair kit GCA modules are shipped
pre-programmed and with upgrade token (part
number 17E206). If software version upgrade is
necessary, follow the procedure in the manual
provided.
ADM
ADM
Update Procedure
Procedure
Update
Procedure
NOTICE
NOTICE
NOTICE
334946H

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents