Calibration Procedure - Graco Reactor 2 H-30 Repair Parts

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Calibration Procedure

Procedure
Calibration
Calibration
Procedure
NOTICE
NOTICE
NOTICE
To prevent damage to the heated hose, a hose
calibration is required if any of the following
conditions are true:
• The hose has never been calibrated before.
• A section of hose has been replaced.
• A section of hose has been added.
• A section of hose has been removed.
NOTE: The Reactor and heated hose must be at the
NOTE:
NOTE:
same ambient temperature to get the most accurate
calibration.
1. Enter Setup Mode and navigate to System
screen 3, then press the Calibrate soft key
2. Press the Continue soft key
the reminder to have the hose at ambient
conditions.
334946H
3. Wait while the system measures the hose
.
to acknowledge
resistance.
NOTE: If hose heat was on prior to the calibration
NOTE:
NOTE:
procedure, the system will wait up to five minutes
to allow the wire temperature to equalize.
NOTE:
NOTE: The hose temperature must be above 32
NOTE:
°F (0 °C) during calibration.