Pressure Relief
Relief Procedure
Pressure
Pressure
Relief
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure
is manually relieved. To help prevent serious
injury from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the
Pressure Relief Procedure when you stop spraying
and before cleaning, checking, or servicing
equipment.
The Fusion AP gun is shown.
1. Press
to stop the pumps.
2. Turn off all heat zones.
3. Relieve pressure in gun and perform gun
shutdown procedure. See gun manual.
334946H
Procedure
Procedure

Pressure Relief Procedure

4. Close gun fluid inlet valves A and B.
5. Shut off feed pumps and agitator, if used.
6. Route fluid to waste containers or supply tanks.
Turn PRESSURE RELIEF/SPRAY valves (SA,
SB) to PRESSURE RELIEF/CIRCULATION
. Ensure gauges drop to 0.
7. Engage gun piston safety lock.
8. Disconnect gun air line and remove gun fluid
manifold.