Proportioning System - Graco Reactor 2 H-30 Repair Parts

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Troubleshooting

Proportioning System

System
Proportioning
Proportioning
System
Before performing any troubleshooting procedures:
1. Follow
Pressure Relief Procedure, page
PROBLEM
PROBLEM
PROBLEM
Proportioning pump does not hold
pressure when stalled.
Material Imbalance. See
Pressure/Material Imbalance,
page
39.
38
2. Turn the main power switch OFF.
3. Allow equipment to cool.
Problems:
Problems:
Problems:
Try the recommended solutions in the order given for
each problem, to avoid unnecessary repairs. Also,
determine that all circuit breakers, switches, and
controls are properly set and wiring is correct before
47.
assuming there is a problem.
CAUSE
CAUSE
CAUSE
Pump piston or intake valve leaking. 1. Observe gauges to determine
Restriction at the gun.
Inadequate flow from pump;
cavitation.
Pressure relief/circulation valve
leaking back to supply.
SOLUTION
SOLUTION
SOLUTION
which pump is losing pressure.
2. Determine in which direction
the pump has stalled by
observing which directional
icon is displayed on the ADM
Home screen. See Table 1.
3. Repair the valve. See pump
manual.
Clean the gun; see your separate
gun manual.
Increase fluid supply to
proportioning pump:
• Use 2:1 supply pump
• Use minimum 3/4 in. (19 mm) ID
supply hose, as short as practical
Fluid is too thick. Consult
your material supplier for the
recommended fluid temperature to
maintain a viscosity of 250 to 1500
centipoise.
Clean inlet strainer screen.
Worn pump inlet valve ball/seat or
gasket. Replace pump.
Remove return line and determine
if flow is present while in SPRAY
mode.
334946H