Repair Heated Hose - Graco Reactor 2 H-30 Repair Parts

Hydraulic proportioning systems
Hide thumbs Also See for Reactor 2 H-30:
Table of Contents

Advertisement

Repair
Repair Heated
Heated Hose
Hose
Repair
Repair
Heated
Hose
Refer to the heated hose manual 309572 for hose
replacement parts.
Check Hose
Hose Wires
Wires
Check
Check
Hose
Wires
1. Perform
Shutdown, page
NOTE: Whip hose must be connected.
NOTE:
NOTE:
2. Remove cover (CV).
3. Disconnect system wires from the Reactor.
4. Disconnect hose wires (HW) from terminal block
(TB), see Fig 3.
5. Using an ohmmeter, check between the hose
wires (HW). There should be continuity.
6. If hose fails test, retest at each length of hose
from the system out to the gun, including whip
hose, until failure is isolated.
7. Reconnect wires and install cover (CV).
Check
Check
Check RTD
RTD
RTD Cables
Cables
Cables and
1. Perform
Shutdown, page
2. Disconnect RTD cable (C) at Reactor (SC).
3. Test with an ohmmeter between pins of M8 cable
connector C.
NOTE: Do not touch outer ring with test probe
NOTE:
NOTE:
while measuring resistance.
M8 Connector
Connector Pins
Pins
M8
M8
Connector
Pins
3 to 1
3 to 4
1 to 4
2 to any
62
48.
and
and FTS
FTS
FTS
48.
Resistance
Resistance
Resistance
See
RTD Resistance
vs. Temperature,
page
63.
See
RTD Resistance
vs. Temperature,
page
63.
0.2 - 0.4 ohms at the
FTS (each 50 ft cable
adds 2.5 ohms)
infinity (open)
4. Retest at each length of hose, including whip
hose, until failure is located.
5. If the FTS is not reading properly at the end of
the hose, connect FTS directly to RTD cable (C)
at the manifold.
6. If the FTS reads properly at the manifold but
not at the end of the hose, check cable (C)
connections. Verify they are tight.
Heated Hose
Figure 8
NOTE: To assist in taking readings, order RTD
NOTE:
NOTE:
Test Kit 24N365. Kit includes two cables: one
cable with a compatible female M8 connector
and another cable with a male M8 connector.
Both cables have stripped wire at the other end
for easy test probe access.
Pins / / / Wire
Wire Color
Color
Pins
Pins
Wire
Color
3 to 1 / brown to blue
3 to 4 / blue to black
1 to 4 / brown to black
2 to any / N/A
Result
Result
Result
See
RTD Resistance
vs. Temperature,
page
63.
See
RTD Resistance
vs. Temperature,
page
63.
0.2 - 0.4 ohms at the
FTS (each 50 ft cable
adds 2.5 ohms)
infinity (open)
334946H

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents