Replace Flow
Flow Meter
Meter
Replace
Replace
Flow
Meter
NOTE: For H-30, H-40, and H-50 Elite models only.
NOTE:
NOTE:
1. Perform
Shutdown, page
2. Perform
Pressure Relief Procedure, page
3. Disconnect the flow meter cable.
4. Disconnect the hose. Remove the flow meter.
5. Install the new flow meter and reconnect the
hose.
Figure 6 : Flow Meter
6. Connect the flow meter cable.
7. Enter the k-factor on System Screen 3 on
the ADM. Refer to System
operation manual.
334946H
48.
47.
System 3 3 3 in your Reactor
System
Replace Pressure
Pressure Transducers
Replace
Replace
Pressure
1. Flush. See
Flushing, page
2. See
Shutdown, page
3. Disconnect transducer cables (405) from #6 and
#7 connectors on the HCM.
4. Remove wire ties constraining transducer cable
and remove cable from cabinet.
5. Install o-ring (406) on new transducer (405).
6. Install transducer in manifold. Mark end of cable
with tape (red=transducer A, blue=transducer B).
7. Route new cable into cabinet and thread into
bundle as before. Attach cable ties to bundle
as before.
8. Connect A side pressure transducer cable
to HCM port #6. Connect B side pressure
transducer cable to HCM port #7.
Repair
Transducers
Transducers
49.
48.
59