Figure 32 Wipe Off Isolation Valve Components
6. Inspect the fluid hose (HW). Check for any
leakage or bulges in the outer cover which may
indicate an internal leak.
7. Inspect the gun for fluid leaks. See your gun
manual.
3A7312D
Replace the
the Wash
Wash Fluid
Replace
Replace
the
Wash
Check the wash fluid bottle level. If the level changes,
service the isolation valve seals.
1. Prepare the isolation system for service. Follow
the
Prepare the Isolation System for Service,
page
90.
2. Use a flat blade screwdriver to open the cabinet.
3. Slide the electrostatic shield (12) up to remove.
4. To remove the isolation valve cover (99), loosen
the top and bottom screws (99a).
5. Disconnect the push-to-connect tube from the
bottle cap of the wash fluid bottle (W).
6. Lift the sealed wash fluid bottle (W) out of the
system. Fill it with clean HydroShield cleansing
solution above the minimum line marked on the
bottle. Replace it in the cabinet.
7. Reconnect the push-to-connect tube to the bottle
cap of the wash fluid bottle (W).
8. Replace the isolation valve cover (99) and tighten
the top and bottom screws (99a).
9. Reinstall the electrostatic shield (12) inside the
cabinet.
10. Close the cabinet door and use a flat blade
screwdriver to secure the door shut.
Maintenance
Fluid
Fluid
69