LBC-4000 L-Band Up/Down Converter System
Remote Control
Command
Parameter
(Instruction
Type
Code and
qualifier)
Retrieve
N/A
Configuration
Status
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric
Response to
codes, that is, ASCII codes between 48 and 57)
Query
177 bytes
Query only.
alphanumeric
Used to Query the configuration status of the unit
Example: RCS_
FRE_A_01694.765 -> Conv A frequency
ATT_A_03.00
TX_A_ON
SLP_A_0.0
ONL_A_ON
FRE_B_11444.765 -> Conv B frequency
ATT_B_15.00
RX_B_ON
SLP_B_0.0
ONL_B_ON
RED_OFF
AFR_ON
EXT_NO
REF_087
REM_YES
COMM_EIA-232
ADD_0001
BR_9600
FMT_8-N-1
MN/LBC4000.IOM
Revision 2
N/A
-> Conv A attenuation
-> Conv A mute state
-> Conv A slope adj.
-> Conv A on/offline
-> Conv B attenuation
-> Conv B mute state
-> Conv B slope adj.
-> Conv B on/offline
-> Conv redundancy
-> auto flt recovery
-> external ref.
-> ref osc adjust
-> remote mode
-> remote interface
-> remote address
-> remote baud rate
-> remote data format
A-19
Response to
Query
Command
(Instruction
(target to
Code and
controller)
qualifier)
RCS_
Response to
Query
(target to
controller)
RCS_
x....x
(see description for
details of
arguments)

Advertisement