Comtech EF Data LBC-4000 Installation And Operation Manual page 4

L-band up/down converter system
Table of Contents

Advertisement

Command
Parameter
(Instruction
Type
Code and
qualifier)
Concise
N/A
Maintenance
Status
Filename: T_ERRATA
Arguments for
Command or
(Note that all arguments are ASCII numeric codes, that
Response to
is, ASCII codes between 48 and 57)
Query
70 bytes
Query only.
numerical
Used to Query the Maintenance status of the unit in concise
format.
Syntax:
CMS_aaa.abbb.bccc.cddd.deee.efff.fggg.ghhh.hiii.ijjj.jkkk.klll
.lmmm.mnnn.nooo.oppp.pqqq.q'cr''lf'
where:
aaa.a =12 VDC supply #1 in volts
bbb.b = 8 VDC supply #1 in volts
ccc.c = 5 VDC supply #1 in volts
ddd.d = 12 VDC supply #2 in volts
eee.e = 8 VDC supply #2 in volts
fff.f= 5 VDC supply #2 in volts
ggg.g = Ref Osc tuning voltage in volts
hhh.h = Converter A IFLO tuning voltage in volts
iii.i= Converter A RFLO tuning voltage involts
jjj.j = Converter A Input Power in dBm
(Reserved for future use)
kkk.k = Converter A Output Power in dBm
(Reserved for Future use)
lll.l= Converter A temperature in degrees C
mmm.m = Converter B IFLO tuning voltage in volts
nnn.n= Converter B RFLO tuning voltage in volts
ooo.o = Converter B Input Power in dBm
(Reserved for future use)
ppp.p =Converter B Output Power in dBm
(Reserved for future use)
qqq.q = Converter B temperature in degrees C
2
Description of arguments
Response to
Query
Command
(Instruction
(target to
Code and
controller)
qualifier)
N/A
CMS_
Response to
Query
(target to
controller)
CMS_
x....x
(see description for
details of
arguments)

Advertisement

Table of Contents
loading