Comtech EF Data LBC-4000 Installation And Operation Manual page 50

L-band up/down converter system
Table of Contents

Advertisement

LBC-4000 L-Band Up/Down Converter System
Remote Control
Command
Parameter
(Instruction
Type
Code and
qualifier)
Reference
SRO_
Oscillator Adjust
Remote Address
SPA_
Remote Baud
SBR_
Rate
Remote Baud
SBF_
Data Format
Set RTC (Real-
DAT_
Time-Clock)
Date
Arguments for
Description of arguments
Command or
(Note that all arguments are ASCII numeric
Response to
codes, that is, ASCII codes between 48 and 57)
Query
3 bytes,
Command or Query.
numerical
SRO_xxx
Where: x = Ref Osc Adjust, between 000 and 255.
Resolution 001.
Example: SRO=087
Note: SRO cannot be adjusted when the unit is
locked to an external reference source.
4 bytes,
Command or Query.
numerical
SPA_xxxx
Where: xxxx = Set Physical Address-between
0001 to 9999. Resolution 0001
Example: SPA_0412
4 bytes
Command or Query.
SBR_xxxx
Where: xxxx = remote baud rate as follows:
1200 = 1200 baud
2400 = 2400 baud
4800 = 4800 baud
9600 = 9600 baud
19K2 = 19200 baud
38K4 = 38400 baud
1 byte,
Command or Query
value 0 to 2
SBF_x
Where: x = 0 (8N1), 1(7E2), or 2(7O2)
8 bytes,
Command or Query.
numerical
DAT_mm/dd/yy
A command/query in the form mm/dd/yy, where:
dd = day of the month, between 01 and 31, mm =
month of the year, between 01 and 12 and yy =
year, between 00 and 96 (2000 to 2096)
Example: DAT_04/25/03 would be April 25, 2003
MN/LBC4000.IOM
Revision 2
Response to
Command
(target to
controller)
Same as command
Same as command
Same as command
Same as command
Same as command
A-10
Query
Response to
(Instruction
Query
Code and
(target to
qualifier)
controller)
SRO_
SRO_xxx
(see description of
arguments)
SPA_
SPA_xxxx
(see description of
arguments)
SBR_
SBR_xxxx
(see description of
arguments)
SBF_
SBF_x
(see description of
arguments)
DAT_
DAT_mm/dd/yy
(see description of
arguments)

Advertisement

Table of Contents
loading

Table of Contents