3. After entering the change and key definitions, enter the file name, for example
REMMOSS.
4. Enter 1 to select a specification file and enter REMMOSS for the file name.
5. Go to ''Testing the Modem Connection to a Remote Console" on page 11-13
and check the connection to the 3745.
Note: The asynchronous communications adapter should be confjgured as COM1
(the primary adapter) for EIA 232-0 operations.
IBM PS/2 (Remote)
Note: To successfully complete this procedure, you must have installed OS/2
Extended Edition, Version 1.1 or higher, at SYSLEVEL 03030 or higher. Jf you are
not sure of the level, refer to Appendix A.
To configure a PS/2 as a remote console, do the following:
1. Open an OS/2 full screen.
2. Type CD \CMLlB.
3. Type COPY ACSCFG.CFG MOSSREMM.CFG.
4. Type CD \.
5. Edit the CONFIG.SYS file by adding the following line at the end:
DEVICE=C:\CMLIB\ASYNCDDB.SYS COMI
6. Save the CONFIG.SYS file.
Notes:
a. If you are using a PC/AT or a PCIXT equipped with an S0286
microprocessor, type ASYNCDDA.SYS instead of ASYNCDDB.SYS.
b. Open your CONF1G.SYS file and look for the line (or lines):
DEVICE=C:\OS2\COMxx.SYS (where xx = 81, 82, or 83)
If you find it, insert this line before it:
ASYNCDDB/A
7. Open Desktop Manager.
S. Double-click Communication Manager/2 (this takes ten seconds to load).
9. In the CM/2 main menu, select Advanced.
10. Select Configuration.
11. Type MOSSREMM and press Enter.
12. The Communications Configuration menu displays.
13. Select Workstation profile.
14. Select Change and fill in the fields as follows:
Chapter 11. Setting Up a Remote Console