Leaving the Console Configuration
1. Press Ctrl and the Minus key on the numeric keypad.
• Type Y to save the configuration.
• Type N to cancel the new configuration or keep the previous one.
• Type
C
to review the configuration.
3161 or 3163 (Local or Alternate)
1. Hold down the Ctrl key (bottom left) and press the Setup key (top right).
2. Fill in the fields as follows, using the
t
and
~
keys to move between items and
the spacebar to select the parameter values:
Machine Mode
Operating Mode
Interface
Li
ne Control
Line Speed (bps)
Parity
Turnaround Character
Stop Bit
Word Length (bits)
Response Delay
Break Signal (ms)
3. Press Send.
4. Press Select.
5. Use the spacebar to enter as follows:
IBM3101
BLOCK
RS232C
PRTS
2400
EVEN
DC3
1
7 (3161 only)
100 (3161 only)
500 (3161 only)
Scroll=OFF
Return=CR
Line Wrap=ON
Autolf=ON
Send=PAGE
Null Supp=ON
6. Press Select to return.
7. Go to ''Testing a Connection with the Local or Alternate Console" on
page 10-10 for checking the connection to the 3745.
IBM PS/2 (Local or Alternate)
Note: To complete this procedure successfully, you must be running OS/2
Extended Edition, Version 1.1 or higher, at SYSLEVEL 03030 or higher. If you are
not sure of the level, refer to Appendix A.
To configure a PS/2 as a local or alternate console, do the following:
1. Open an OS/2 screen.
2. Type CD \CMUB at the prompt.
3. Type
COpy ACSCFG. CFG MOSSLOC. CFG.
at the prompt.
10-6