31. Press Esc twice to display the Communications Configuration menu.
32. Select Verify, then Run Verify. The Verified message displays. If the
message does not display, check that you have entered the data correctly.
Press Enter.
33. Select Exit.
34. Select Exit communication configuration.
35. Select Exit.
36. Select Exit Communication Manager.
37. Select Yes.
38. When the Display Feature Status screen disappears, select F3=Exit.
39. The Start Programs menu displays.
40. Select OS/2 full-screen command prompt.
41. Use the system editor to create a STARTUP .CMD file with the following lines:
@ECHO OFF
CD\CMLIB
START "COMM.MGR MOSSL" /FS /N DMPC ACS.CNF /A:ACS ACS.EXE
EXIT
42. Restart the system by simultaneously pressing Ctrl, Alt, and Del.
43. Go to "Testing a Connection with the Local or Alternate Console" on
page 10-10 and check the connection to the 3745.
Note: When you finish a communications task, CM/2 should be closed carefully.
For more information, refer to Appendix A.
MOSS Local or Alternate Console Emulation with CM/2 and Softerm
3727
For a description of how to set up a 3101 terminal emulator, using CM/2 and
Softerm as a connections to 3745 MOSS, see "MOSS Remote Console Emulation
with CM/2 and Softerm" on page 11-10.
Attention - - - - - - - - - - - - - - - - - - - - - - - - ,
The Baud Rate for a local or alternate console is 2400 bps.
Call your IBM service representative.
Chapter 10. Setting Up a Local or an Alternate Console
10-9