Chapter 3
VXI-MXI-2 Configuration and Installation
From Onboard Oscillator
W3
From SMB (S3 must be set to "IN")
From MXIbus
a. CLK10 Generated from Onboard Oscillator (Default)
From Onboard Oscillator
W3
SMB CLK10 Direction
From SMB (S3 must be set to "IN")
From MXIbus
b. CLK10 Generated from SMB
From Onboard Oscillator
W3
From SMB (S3 must be set to "IN")
Receive CLK10 from MXIbus
From MXIbus
S7
c. CLK10 Generated from MXIbus
Figure 3-5. VXIbus CLK10 Routing
The VXI-MXI-2 can also be configured to drive the external CLK SMB
signal from the VXIbus CLK10 signal. Switch S3 controls whether the
VXI-MXI-2 drives or receives the external CLK SMB signal. If you change
the S3 setting to drive CLK10 out the external CLK10 SMB connector, do
not set the W3 jumper to receive the SMB CLK10 signal; instead use the
settings shown in either Figure 3-5a or Figure 3-5c as appropriate.
© National Instruments Corporation
3-9