Fluid Heaters (If Supplied); Pressure Transducers - Graco Reactor E-10 Instructions-Parts List Manual

Plural component proportioner
Hide thumbs Also See for Reactor E-10:
Table of Contents

Advertisement

Fluid Heaters (if supplied)

See your heater manual for repair and parts information,
which is supplied with heated units.
1. Follow Before Beginning Repair, page 36.
2. Follow the Pressure Relief Procedure, page 22.
3. The control section of the heater can be repaired in
place. Remove the heater to clean the fluid section.
See your manual for repair and parts information.
58
Heated Units
F
. 15 Transducers
IG
311075ZAB
60
TI7026a

Pressure Transducers

1. Follow Before Beginning Repair, page 36.
2. Follow the Pressure Relief Procedure, page 22.
3. Remove the access cover (39) at the back of the
control module to expose control board (406).
4. Disconnect the transducer cables from J3 and J8 at
the board. See F
IG
connections and check if the status code follows the
bad transducer. See Status Code 3: Transducer A
Failure, page 31.
5. Reconnect the good transducer to the proper
connector. Disconnect the failed transducer from
the board, and unscrew from the base of the fluid
heater (heated units) or transducer manifold
(nonheated units).
6. Install the o-ring (60) on the new transducer (58),
F
. 15, page 43.
IG
7. Install the transducer in the heater or manifold. Mark
the board end of cable with tape (red= transducer A,
blue= transducer B).
8. Route the cable through the channel to the control
module.
9. Connect the transducer cable at the board; see F
14, page 42.
Nonheated Units
. 14, page 42. Reverse A and B
58
60
TI7027a
Repair
.
IG
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

249570 a249571 a249572 a249576 a249577 a

Table of Contents