Purge The Gun Hoses (Nonheated Units Only) - Graco Reactor E-10 Instructions-Parts List Manual

Plural component proportioner
Hide thumbs Also See for Reactor E-10:
Table of Contents

Advertisement

8. Wipe out any remaining material from the supply
tanks. Fill each supply tank with 1-2 gal. (3.8-7.6 l)
of solvent recommended by your material
manufacturer.
9. Set the function knob to Fast Recirc
solvent through system to waste containers.
10. When nearly clear solvent comes from the
recirculation tubes, set function knob to Park
Return the recirculation tubes to the supply tanks.
11. Set the function knob to Fast Recirc
solvent through the system for 10-20 minutes to
ensure thorough cleaning.
12. If using a non-heated unit, purge the gun hose.
Follow Purge the Gun Hoses (Nonheated Units
Only).
311075ZAB
13. Set the function knob to Park
. Pump
14. Solvent flushing is a two step process. Go back to
step 4, drain solvent, and flush again with fresh
solvent.
15. Leave the unit filled with solvent, plasticizer, clean
motor oil, or refill the supply tanks with new material
and reprime.
.
NOTE: Never leave the unit dry unless it has been
disassembled and cleaned. If fluid residue dries in the
pumps, the ball checks may stick the next time you use
the unit causing diminished performance and damage to
the system.
Purge the Gun Hoses
(Nonheated Units Only)
NOTE: To flush the gun, refer to your gun instruction
manual.
. Circulate
Disconnect hoses from the gun and secure back into the
tanks for thorough cleaning with solvent.
1. Turn Spray valve A to Spray.
2. Open the gun into waste container A.
3. Set the function knob to Slow Recirc
hose is flushed.
4. Set the function knob to Park
5. Repeat for side B.
Flushing
.
until the
.
29