Repair

Repair

Before Beginning Repair

Repairing this equipment requires access to parts
which may cause electric shock or other serious injury
if work is not performed properly. Be sure to shut off
all power to the equipment before repairing
1. Flush the system if possible. See Flushing, page
28. If not possible, clean all parts with solvent
immediately after removal, to prevent isocyanate
from crystallizing due to moisture in the
atmosphere.
2. Set the function knob to Park
3. Shut off Motor Power. Disconnect the power supply.
4. Shut off the Heater Power. Allow the equipment to
cool before repairing.
5. Follow the Pressure Relief Procedure, page 22.
36

Remove Supply Tanks

Refer to your displacement pump manual for repair and
parts information.
1. Follow Before Beginning Repair, page 36.
2. Follow the Pressure Relief Procedure, page 22.
3. Close both fluid inlet ball valves (52).
.
NOTE: Use dropcloth or rags to protect Reactor E-10
and surrounding area from spills.
4. Open the filter drain plug on Y-strainer (51).
5. Disconnect the swivel elbow (50) at the pump fluid
6. Remove the screws (4) holding the tank to the cart
7. Pivot the top of the tank to the side and lift it and the
50
51
inlet.
frame.
fluid inlet fittings off of the cart.
52
311075ZAB