The system should respond DCH N EST OPER, meaning that the D-channel
is established and operational.

Software enable the NTAK09 card

Use step 1 to enable NTAK09 DTI/DTI card. If the clock controller and
D-channel interface are not enabled in step 1, go to step 2.
Step 1:
Software enable all NTAK09 DTI/DTI cards using LD 60:
ENLL C
Where C is the DTI/DTI card number (DLOP). The card number
associated with a DTI/DTI card is based on the slot in which the card is
installed.
Note: The DCHI and DTI cards must be programmed prior to software
enabling the NTAK09. Refer to the section "Program Basic PRI" on
page 27 for further information.
Under normal conditions, this step enables the clock controller and
D-channel interface. If enable fails, go to step 2.
Step 2: (if required):
Software enable the clock controller using LD 60. Enable clock tracking on
primary digital card by issuing the following command:
ENL CC 0
Software enable the NTAK93 (DCHI) daughterboard using LD 96
command
ENL DCHI N
(where N is the DCHI I/O address).