HMR Series Positioners
9.8
Disassembly of Drive Type Belt
If present, the IP54 cover must be removed as per section 7.4.1 .
The belt tensioning block needs to be removed on both sides. Following the procedure is described for one side.
• Loosen the carriage cover in order to reach the parts underneath.
Nut tension pin
Lock screw
• Remove the lock screws.
• Loosen the nut of the tension pin a bit and release the pin.
Clamping
plate
• Loosen the screws of the clamping plate and remove it.
• Pull out the belt clamping assembly.
Carriage end cap
Tension pin
Belt clamping assembly
35
WWW.PARKERMOTION.COM
PH: (724)-861-8200