7.2 Security

DDS 5900 components use a proprietary codec algorithm
to prevent unauthorized devices from listening to the
audio signal. To further protect the discussion, assign a
password to the browser interface and enable security
features on wireless routers.
7.2.1 Password Protect the Browser Interface
Assign a password to restrict access to the browser
interface. A password will enable only an administrator or
technician to change system and meeting settings.
1. Connect a computer to the DC 5905 Central Unit (CU).
2. Access the browser interface using the CU hostname or
IP address.
7.2.2 Removing the Password
To clear the password access to the CU, restore factory
default settings.
Note: Resetting to factory defaults will erase all delegate, system, and IP settings.
From the Hardware
a) Go to the front panel of the CU.
b) Scroll the main menu to Restore  Factory  Defaults
c) Press the center button to enter menu
7.2.3 Isolating the Network
For maximum security, isolate the DCS-LAN network with
a dedicated computer or a protected router.
• Dedicate one computer for DDS 5900 control. Connect
it directly to the CU
LAN
devices cannot access the IP address of the control
software.
• If multiple computers or tablets are required, assign a
password encryption for the router. The most effective
standard is the Wireless Protected Access II (WPA2),
which uses Advanced Encryption Standard (AES) for
encryption. Reference the router user guide to set it up.
port. This ensures that wireless
3. Go to the Security page (
4. Enter a valid user name and password.
5. Select Change Password to save the login information.
Note: The user name and password are deleted
when the system is reset to factory default settings.
d) Press the center button again to confirm the reset.
e) Wait for the system to reboot. The computer will lose connection
to the browser interface during this time.
From the Browser Interface
f) Open the CU browser interface
g) Go to Configuration > Factory  Defaults
h) Select the Reset button to reset the system.
i) Wait for the system to reboot. During the reboot process, the
computer cannot access the browser interface.
>
)