Shure DDS 5900 User Manual page 26

Digital discussion system
Hide thumbs Also See for DDS 5900:
Table of Contents

Advertisement

5.5.2 Alternative Setup
Without LS 5900 F Loudspeaker
The CU 5905 supports additional discussion units when the loudspeaker is not used with the DC 5900 F Flushmount
discussion unit. The numbers listed below are calculated with a DIS GM gooseneck microphone.
The flushmount units also operate with the Shure MX4xx series gooseneck microphones, though the power
consumption is slightly higher. Subtract six units from numbers below to determine the maximum number supported
by the CU 5905.
1 Meter between Discussion Units
Distance to DU chain
One Chain
10
57
30
51
50
44
100
21
2 Meter between Discussion Units
Distance to DU chain
One Chain
10
50
30
45
50
36
100
11
5.5.3 Using Junction Boxes
The JB 604 junction box adds four additional outputs to a point on the DCS-LAN chain. These four outputs are available
for short-run connections to DUs, protecting the DCS-LAN chain from technical failures or hot-plugging damage. A single
DU can connect to each JB output, with a maximum cable length of 10 m.
1 Chain
Length to First
Length Between
DU
each JB 6104
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
2 Chains
Length to First
Length Between
DU
each JB 6104
10 m
1 m
30 m
1 m
50 m
1 m
100 m
1 m
5.5.4 Adding Additional Power or Data Refreshing
Equipment can be added to the chain if the installation requires more discussion units.
Model
EX 6010 Extension Unit (4 outputs)
PS 6001 Power Kit
Two Chains
64
60
58
42
Two Chains
60
56
48
22
Number of JB 6104
Maximum
Number of DUs
22
54
20
39
15
34
7
21
Number of JB
Maximum Number of
6104
DUs
26
54
24
48
24
48
16
32
Additional Delegate Units
4x 64 units
57 units