6. Setting pulse-output operation
Using pulse-output operation, the Time Switch can be set to operate
at the same time every day for a fixed period.
【Example】 Setting the Time Switch to turn ON for 30 s from 8:25 am,
Monday to Friday.
Non-operation
Operation
Day
SU
8:25 am
①  Enter operation time setting mode using the
Key. The
MODE
②  Press the
TMR / P
for pulse-output operation. The
flashes. (The Time Switch is set for timer
operation at the time of delivery.)
③  Set the pulse width to 30 s using the
Key. (The pulse width can be set in the range
1 to 59 s or 1 to 60 min.)
④  Press the
Operation
Day
Day
MO
TU
30s
symbol flashes.
Key to set the Time Switch
Key.
WRITE
Operation
Operation
Day
Day
WE
TH
symbol
P
m/ P WD
- 13 -
Operation
Non-operation
Day
Day
FR
SA
The color indicates flashing
SU MO TU WE TH FR SA
-- --
PW
SU MO TU WE TH FR SA
--
P
PW
SU MO TU WE TH FR SA
30
P
PW
SU MO TU WE TH FR SA
-- --
P
PW
1
P 
P 
s
P 
1
P 