Lennox G60UHV Series Installation Instructions Manual page 48

Hide thumbs Also See for G60UHV Series:
Table of Contents

Advertisement

COOLING SEQUENCE
O F OPERATION
I
I
I
POWER ON
I
4,
IS POLARITY
REVERSED?
I
IS THERE
NO
PROPER GROUND?
9
_ YES
THERMOSTAT
CALLS FOR FIRST-STAGE
COOL.
I
4,
COMPRESSOR
AND CONDENSER
FAN
ENERGIZED.
4,
INDOOR BLOWER ENERGIZED
ON FIRST STAGE
COOL SPEED AFTER 2 SECOND DELAY.
SIGNAL POLARITY
REVERSED.
CONTROL WILL CONTINUE TO CALL FOR COOLING
IN THIS CONDITION,
STATUS ERROR CODE 5 + 4.
SIGNAL IMPROPER
GROUND AT LED.
CONTROL WILL CONTINUE TO CALL FOR COOLING
IN THIS CONDITION,
STATUS ERROR CODE 5 + 3.
4,
_1
FIRST-STAGE
DEMAND FOR COOL SATISFIED?
I THERMOSTAT
CALLS FOR SECOND-STAGE
COOL,
4,
I ,NDOOR
BLOWER
RAMPS
UP TO SECOND-STAGE
COOL
SPEED I
4,
ISECOND-STAGE
DEMAND
FOR C OOL SAT'SF'ED?
I
YES 4,
I
I_
COMPRESSOR
AND CONDENSER
FAN DE-ENERGIZED.
NDOOR BLOWER DE-ENEG ZED.