CONTINUED
HEATING SEQUENCE OF OPERATION
SEE BOX A
NORMAL OPERATION.
SEE BOX B
THERMOSTAT
CALLS FOR HEAT.
I
SECOND-STAGE
(HIGH FIRE) HEAT
PRESSURE
SWITCH CLOSED?
YES _
I
HEAT DEMAND SATISFIED?
STATUS LED -- HEARTBEAT.
YES
YES 1
[
SINGLE-STAGE
THERMOSTAT
MODE
1
I '
(DiP SWITCH SET AT "SINGLE")
I
I
I
L
1
I.
YES
I
GAS VALVE OFF, COMBUSTION
AIR
INDUCER OFF AFTER 5-SECOND
LOW SPEED POST PURGE PERIOD,
INDOOR BLOWER OFF DELAY
INITIATED ON LOW HEAT SPEED,
STATUS LED - HEARTBEAT.
DEMAND FOR HEAT SATISFIED.
POWER ON STAND BY.
STATUS LED -- PULSE.
I
I
NO
I
RETURN TO FIRST-STAGE
HEAT MODE.
FIRST-STAGE
CONTINUES
UNTIL SECOND-
STAGE PRESSURE
SWITCH CAN BE PROVEN
or HEAT DEMAND IS SATISFIED. A FIVE (5)
MINUTE WAIT PERIOD IS INITIATED BEFORE
RETRY. WERE 5 ATTEMPTS
MADE FOR
SECOND-STaGE
HEAT?
NO
,_
SEE BOX C
FIRST-STAGE
HEAT DEMAND SATISFIED?
I
TWO STAGE THERMOSTAT
MODE?
3,
(DIP SWITCH SET AT "TWO")
I
J
YES'f
._
SECOND STAGE HEAT
FIRST AND SECOND STAGE HEAT
DEMAND SASTISFIED?
DEMAND SATISFIED SIMULTANEOUSLY.
STATUS LED -- HEARTBEAT.
STATUS LED -- HEARTBEAT.
YES _
I
GAS VALVE, COMBUSTION
AIR INDUCER
AND INDOOR BLOWER RETURN TO FIRST-
STAGE OPERATION.
STATUS LED -- HEARTBEAT.
I
FIRST STAGE HEAT DEMAND SATISFIED?
I
YES
4
GAS VALVE OFF. COMBUSTION
AIR INDUCER
OFF AFTER 5-SECOND LOW SPEED POST-
PURGE PERIOD. INDOOR BLOWER OFF.
DELAY INITIATED ON LOW HEAT SPEED,
STATUS LED -- PULSE,
Page 47